updatedAt: 2026-02-09T11:37:39.000Z
agentTools:
  projectIndex: https://docs.zaptec.com/llms.txt
---

# Zaptec Go OCPP 1.6J Non-standard implementation guide

The Zaptec Go OCPP1.6J Non-standard implementation guide provides detailed information on the Zaptec Go's OCPP implementation. Specifically, it highlights the characteristics, variations, and extensions that are unique to this implementation compared to the standard OCPP protocol. This guide is intended for integrators, developers, and operators to facilitate a clear understanding and successful interaction with Zaptec Go charging stations.

## 1. Configuration Key Names & Values

### 1.1. FreeChargingIdTag

| Field             | Value                                                                                                                                                         |
| ----------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Required/optional | required                                                                                                                                                      |
| Accessibility     | RW                                                                                                                                                            |
| Type              | CiString20Type                                                                                                                                                |
| Description       | idToken used as part of `StartTransaction.req` when no other idToken is specified. This SHOULD only be used by the Charge Point when FreeCharging is enabled. |

***

### 1.2. FreeCharging

| Field             | Value                                                                               |
| ----------------- | ----------------------------------------------------------------------------------- |
| Required/optional | required                                                                            |
| Accessibility     | RW                                                                                  |
| Type              | boolean                                                                             |
| Description       | Whether the Charge Point will start charging without requiring idTag authorization. |

***

### 1.3. LockCablePermanently

| Field             | Value                                                                                                                                                                                                                                         |
| ----------------- | --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Required/optional | required                                                                                                                                                                                                                                      |
| Accessibility     | RW                                                                                                                                                                                                                                            |
| Type              | boolean                                                                                                                                                                                                                                       |
| Description       | Whether the Charge Point SHALL lock the cable in place after insertion, and thereafter act as if the cable is permanently attached. If `true`, then the `UnlockConnectorOnEVSideDisconnect` configuration key SHALL be `false` and read-only. |

***

### [1.4. PowerActiveImportDeltaForEagerMeterValueSample](https://docs.zaptec.com/docs/poweractiveimportdeltaforeagermetervaluesample)

| Field             | Value                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        |
| ----------------- | -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Required/optional | required                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     |
| Accessibility     | RW                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           |
| Type              | integer                                                                                                                                                                                                                                                                                                                                                                                                                                                                                      |
| Unit              | W                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            |
| Description       | Maximum change in `Power.Active.Import` since the last MeterValue related to `MeterValuesSampledData` before a new `Sample.Periodic` is sent and `MeterValueSampleInterval` is reset. A value of `0` disables this behaviour. <br /><br />**Example:** If set to `200` and `MeterValueSampleInterval` is `3600`, and `Power.Active.Import` was `300` during the last sample, then if it becomes > `500` or < `100`, it will send a new `Sample.Periodic` immediately and reset the interval. |

***

### 1.5. UseAuthorizationKeyWithoutDecoding

| Field             | Value                                                                                                                                                                                                                                                                                                                                                                  |
| ----------------- | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Required/optional | required                                                                                                                                                                                                                                                                                                                                                               |
| Accessibility     | RW                                                                                                                                                                                                                                                                                                                                                                     |
| Type              | boolean                                                                                                                                                                                                                                                                                                                                                                |
| Description       | Alters the charger's validation and use of `AuthorizationKey`. <br /><br />**If false:** Tries to decode hex-encoded `AuthorizationKey` and rejects invalid ones (per RFC 7617 and 5234). <br />**If true:** Uses it directly as HTTP Basic Auth password with similar validation but no decoding.<br /><br />**Default:** `false` if not previously set, else `true`. |