# PowerActiveImportDeltaForEagerMeterValueSample

`PowerActiveImportDeltaForEagerMeterValueSample` controls **when the charger sends extra (eager) `MeterValues`** based on changes in imported active power (P).

Think of it like a **speedometer for power (in watts)**:

* The charger normally sends power readings every *X* seconds (`MeterValueSampleInterval`).
* This key sets **how big a power change** must happen before the charger sends an **extra reading immediately**, instead of waiting.

## Behaviour

* If the power change is **greater than this value** → send an extra `MeterValues` now.
* If the power change is **smaller** → wait for the normal interval.

## Key details

* Name: `PowerActiveImportDeltaForEagerMeterValueSample`
* Type: number
* Unit: watts (W)
* `0` → no extra readings, only the normal periodic ones
* Smaller value → more frequent extra samples (more detail, more traffic)
* Larger value → extra samples only on big changes (less detail, less traffic)

## Example 1

* `MeterValueSampleInterval = 3600` (once per hour)
* Last power value: `300 W`
* `PowerActiveImportDeltaForEagerMeterValueSample = 200`

Then:

* If power goes **above 500 W** or **below 100 W**, the charger:
  * Immediately sends a new `MeterValues` reading
  * Restarts the one‑hour timer

## Example 2

* `PowerActiveImportDeltaForEagerMeterValueSample = 500`

Then:

* The charger sends an extra `MeterValues` whenever imported active power changes by **more than 500 W** from the last reported sample.

## How to update the key (ChangeConfiguration)

Send a `ChangeConfiguration` CALL from the CSMS to the Charging Station:

```json
[
  2,
  "12345678-90ab-cdef-1234-567890abcdef",
  "ChangeConfiguration",
  {
    "key": "PowerActiveImportDeltaForEagerMeterValueSample",
    "value": "500"
  }
]
```