updatedAt: 2026-06-16T14:13:14.000Z
agentTools:
  projectIndex: https://docs.zaptec.com/llms.txt
---

# Send charger command

<b>Permissions:</b> Requires owner or service-level access.

<b>Supported Command IDs:</b>

            - <b>102</b> – Restart the charger

            - <b>200</b> – Upgrade charger firmware

            - <b>506</b> – Stop or pause charging

            - <b>507</b> – Resume charging

            - <b>10001</b> – Deauthorize and stop charging

<b>Command 10001 – Deauthorize and Stop:</b>

            The caller must ensure that no new charging sessions are authorized until the command is completed.

<b>Command 506 – Pause/Stop Charging:</b>

                - Requires firmware version > 3.2 on PRO chargers

                - Typical usage: For chargers in active charging mode (state <b>ChargeOperationMode, 710</b> = 3). Other edge cases are supported,
            but this is the most common scenario.

                - The command will be rejected if the charger is already paused (state <b>ChargeOperationMode, 710</b> = 5 and <b>FinalStopActive, 718</b> = 1)
                or disconnected (state <b>ChargeOperationMode, 710</b> = 1)
<b>Commands 507 – Resume Charging:</b>

                - Requires firmware version > 3.2 on PRO chargers

                - Typical usage: For chargers in paused state (state <b>ChargeOperationMode, 710</b> = 5 and <b>FinalStopActive, 718</b> = 1).
            Other edge cases are supported, but this is the most common scenario.

            - The command will be rejected if the charger is not in paused mode (state <b>ChargeOperationMode, 710</b> = 5 and <b>FinalStopActive, 718</b> = 1)

                neither Scheduler is active (state <b>NextScheduleEvent, 763</b> is set)


# OpenAPI definition

```json
{
  "openapi": "3.0.4",
  "info": {
    "title": "Zaptec API",
    "version": "v1"
  },
  "servers": [
    {
      "url": "https://api.zaptec.com"
    }
  ],
  "paths": {
    "/api/chargers/{id}/sendCommand/{commandId}": {
      "post": {
        "tags": [
          "Charger"
        ],
        "summary": "Send charger command",
        "description": "<b>Permissions:</b> Requires owner or service-level access.\n\n<b>Supported Command IDs:</b>\n\n            - <b>102</b> – Restart the charger\n\n            - <b>200</b> – Upgrade charger firmware\n\n            - <b>506</b> – Stop or pause charging\n\n            - <b>507</b> – Resume charging\n\n            - <b>10001</b> – Deauthorize and stop charging\n\n<b>Command 10001 – Deauthorize and Stop:</b>\n\n            The caller must ensure that no new charging sessions are authorized until the command is completed.\n\n<b>Command 506 – Pause/Stop Charging:</b>\n\n                - Requires firmware version > 3.2 on PRO chargers\n\n                - Typical usage: For chargers in active charging mode (state <b>ChargeOperationMode, 710</b> = 3). Other edge cases are supported,\n            but this is the most common scenario.\n\n                - The command will be rejected if the charger is already paused (state <b>ChargeOperationMode, 710</b> = 5 and <b>FinalStopActive, 718</b> = 1)\n                or disconnected (state <b>ChargeOperationMode, 710</b> = 1)\n<b>Commands 507 – Resume Charging:</b>\n\n                - Requires firmware version > 3.2 on PRO chargers\n\n                - Typical usage: For chargers in paused state (state <b>ChargeOperationMode, 710</b> = 5 and <b>FinalStopActive, 718</b> = 1).\n            Other edge cases are supported, but this is the most common scenario.\n\n            - The command will be rejected if the charger is not in paused mode (state <b>ChargeOperationMode, 710</b> = 5 and <b>FinalStopActive, 718</b> = 1)\n\n                neither Scheduler is active (state <b>NextScheduleEvent, 763</b> is set)\n",
        "operationId": "api_chargers_{id}_sendcommand_{commandid}_post",
        "parameters": [
          {
            "name": "id",
            "in": "path",
            "description": "Unique identifier of the charger.",
            "required": true,
            "schema": {
              "type": "string",
              "format": "uuid"
            }
          },
          {
            "name": "commandId",
            "in": "path",
            "description": "The ID of the command to execute.",
            "required": true,
            "schema": {
              "type": "integer",
              "format": "int32"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "OK"
          },
          "401": {
            "description": "Unauthorized"
          },
          "403": {
            "description": "Forbidden"
          }
        },
        "security": [
          {
            "ory_auth": []
          }
        ]
      }
    }
  },
  "components": {
    "securitySchemes": {
      "ory_auth": {
        "type": "oauth2",
        "flows": {
          "password": {
            "tokenUrl": "https://api.zaptec.com/oauth/token",
            "scopes": {}
          }
        }
      }
    }
  },
  "tags": [
    {
      "name": "Charger"
    }
  ]
}
```