Permissions: Requires owner or service-level access.
Supported Command IDs:
- 102 – Restart the charger
- 200 – Upgrade charger firmware
- 506 – Stop or pause charging
- 507 – Resume charging
- 10001 – Deauthorize and stop charging
Command 10001 – Deauthorize and Stop:
The caller must ensure that no new charging sessions are authorized until the command is completed.
Command 506 – Pause/Stop Charging:
- Requires firmware version > 3.2 on PRO chargers
- Typical usage: For chargers in active charging mode (state ChargeOperationMode, 710 = 3). Other edge cases are supported,
but this is the most common scenario.
- The command will be rejected if the charger is already paused (state ChargeOperationMode, 710 = 5 and FinalStopActive, 718 = 1)
or disconnected (state ChargeOperationMode, 710 = 1)
Commands 507 – Resume Charging:
- Requires firmware version > 3.2 on PRO chargers
- Typical usage: For chargers in paused state (state ChargeOperationMode, 710 = 5 and FinalStopActive, 718 = 1).
Other edge cases are supported, but this is the most common scenario.
- The command will be rejected if the charger is not in paused mode (state ChargeOperationMode, 710 = 5 and FinalStopActive, 718 = 1)
neither Scheduler is active (state NextScheduleEvent, 763 is set)
post https://example.com/api/chargers//sendCommand/