Update installation

Updates installation properties (requires owner or service permissions).

Available Current: Provide eitherAvailableCurrent
or (AvailableCurrentPhase1, AvailableCurrentPhase2, AvailableCurrentPhase3).


Updating available current will instantly trigger phase and load balancing for the installation.
Vehicles will adjust their charging settings within 5 seconds.


Usage Recommendations:

  • Do not update this setting more than once every 15 minutes to prevent charging interruptions.
  • Available current is limited to the installation’s configured maximum current (circuit breaker current).
  • If set to null (not provided), the installation will revert to its maximum current setting.
Language
Credentials
OAuth2